Standard

GB/T 48023-2026: Data Center Cold Plate Liquid Cooling System Technical Specifications

China's first data center liquid cooling national standard, GB/T 48023-2026: published Jul 30, 2026, effective Feb 1, 2027, drafted by a Sugon subsidiary.

One-line summary

GB/T 48023-2026, Technical specifications for cold plate liquid cooling system of data center, is China's first national standard for data center liquid cooling. Published July 30, 2026, effective February 1, 2027; drafted by Sugon's subsidiary and managed by the National Information Technology Standardization Committee.

Standard Overview ​

ItemDetail
Standard numberGB/T 48023-2026
Standard nameTechnical specifications for cold plate liquid cooling system of data center
Issuing bodyState Administration for Market Regulation (SAC), 2026 No. 33 national standard announcement
Date of publicationJuly 30, 2026
Effective dateFebruary 1, 2027
Technical committeeNational Information Technology Standardization Committee (managed by CESI)
Lead drafterSugon Digital (a subsidiary of Dawning/Sugon)
StatusTo be implemented

Scope ​

The standard applies to the design, manufacturing, installation and testing of cold plate liquid cooling systems in data centers, covering the use of cold plate liquid cooling for heat dissipation of servers and other IT equipment. As China's first national standard for data center liquid cooling, it provides a unified technical basis for data center builders and operators adopting cold plate liquid cooling.

Key Clause Points ​

ClauseContentAffected parties
System composition and terminologyDefines the composition and terms of cold plate liquid cooling systemsLiquid cooling manufacturers, data center builders
Technical requirementsSpecifies technical indicators for key components such as cold plates, piping and coolantComponent and system suppliers
Testing methodsSpecifies test and verification methods for system performance and safetyTesting bodies, system integrators
Installation and operationSpecifies installation, operation and maintenance requirementsData center operators

Note: Clause details are subject to the official published text of GB/T 48023-2026; the table above is compiled from the standard announcement and public information from the managing institution.

Compliance Advice ​

  • Data center builders and liquid cooling suppliers should align current and planned projects with the standard before it takes effect on February 1, 2027.
  • Suppliers should incorporate the standard's technical indicators into product design, factory testing and quality documentation, so products can be verified against GB/T 48023-2026.
  • Operators should require suppliers to provide test reports demonstrating compliance with GB/T 48023-2026 when procuring liquid cooling systems.

Official Sources ​